BPQDV - 1792, OVER-COAT

Product Identification

Product ID:1792, OVER-COAT
MSDS Date:03/15/1989
FSC:6810
NIIN:00N033230
MSDS Number: BPQDV

Responsible Party
CERTIFIED LABS DIV OF NCH CORP
IRVING, TX 75015
US

Emergency Phone: 214-438-1381

Info Phone: 214-438-1381

Preparer: RICHARD STOLLEY

Cage: 20913

Contractor
NCH CORP
152170 IRVING, TX 75015-2170 US

Telephone: 972-438-0563

Cage: 20913

Ingredients

LIGROINE; (ALIPHATIC PETROLEUM DISTILLATE)

CAS: 8032-32-4

RTECS: OI6180000

OSHA PEL 500 PPM (MFR)

ACGIH TLV: 100 PPM (MFR)


ETHANE, 1,1,1-TRICHLORO-; (1,1,1-TRICHLOROETHANE)

CAS: 71-55-6

RTECS: KJ2975000

Fraction By Weight: 30%

OSHA PEL 350 PPM;450 PPM STEL

ACGIH TLV: 350 PPM;450 PPM STEL

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CHLOROCARBON MATLS HAVE PRODUCED
SENSIT OF MYOCARDIUM TO EPINEPHRINE IN LAB ANIMALS & COULD HAVE
SIMILAR EFT IN HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE
CONTRAINDICATED EXCEPT FOR LIFE-SUSTAI NING USES IN HUMANS
ACUTELY/CHRONICALLYEXPOSED TO CHLOROCARBONS . ACUTE:CAN LEAD TO CNS
DEPRESS,(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:HDCH/DIZZ, NAUS & LOSS OF
CONSCIOUSNESS. PROD MAY IRRIT SKIN & WOULD YIELD MARKED IRRIT TO
EYES, CAUSING REDDNESS/TEARING. CHRONIC:CNS DEPRESS, KIDNEY DMG,
DERM & POSS CANCER. TOX BY PRLNGD I NHAL/CONT W/SKIN. TOX TO
MUCOSA. CAN CAUSE EYE DMG, SYSTEMIC & OTHER EFTS. EXCESS EXPOS MAY
CAUSE CNS, LIVER/KIDNEY EFT.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:MOVE TO FRESH AIR & TREAT SYMPTOMATICALLY. GIVE O*2 IF
BRTHG IS DFCLT, GIVE ARTIF RESP IF BRTHG STOPS. GET MD HELP.
EYE:FLUSH W/WATER FOR AT LEAST 15 MIN. HOLDING EYELIDS OPEN OCCAS.
SEE MD IF I RRIT PERSISTS. SKIN:WASH W/SOAP & WATER. INGEST:DO NOT
INDUCE VOMIT EVEN IF VOMIT OCCURS. IF IT OCCURS, KEEP HEAD BELOW
HIPS TO PREVENT ASPIRATION OF LIQ INTO LUNGS. GET MD ATTN IMMED.
(SUPDAT)

Fire Fighting

Flash Point Method:TOC
Flash Point:85F,29.4C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA
AND FULL PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:THERMAL DECOMPOSITION PRODUCTS MAY
INCLUDE HCL . UNDER CERTAIN FIRE CONDITIONS SMALL AMOUNTS OF
PHOSGENE CAN BE FORMED.

Accidental Release

Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT, PREVENT FROM
ENTERING SEWER/WATER SOURCES. VENT ENCLOSED SPACE. WEAR RESP. CLEAN
UP (ANY ELEC CLEANING EQUIP MUST BE EXPLOS PROOF) OR SOAK UP
W/SAND, COTTON WASTE OR OTHER ABSORBENT MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE TEMPS:MAX:120F MIN:30F. FOLLOW
LABEL DIRECTIONS. KEEP OUT OF REACH OF CHILDREN.
Other Precautions:NO SMOKING IN AREA OF USE. DO NOT USE IN GENERAL
VICINITY OF ARC WELDING, OPEN FLAMES OR HOT SURFACES. HEAT AND/OR
UV RADIATION MAY CAUSE FORMATION OF HCL AND/OR PHOSGENE .

Exposure Controls

Respiratory Protection:NONE REQUIRED WITH PROPER VENTILATION. HOWEVER,
THIS DOES NOT PRECLUDE USE OF PROPER NIOSH/MSHA APPROVED
RESPIRATORS IN EMERGENCY CONDITIONS.
Ventilation:SUFFICIENT VENTILATION TO BE EQUAL TO OR BELOW ALLOWED
CONCENTRATION. USUALLY GENERAL EXHAUST IS ADEQUATE.
Protective Gloves:VITON, PVA/EQUIVALENT GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:APRON.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRST AID PROC:NOTES TO MD:DEPENDING ON AMOUNT INGESTED AND RETAINED AS
WELL AS TOXICITY OF PRODUCT, GASTRIC LAVAGE SHOULD BE CONSIDERED.
KEEP PATIENTS HEAD BELOW HIPS TO PREVENT PULMONARY ASPIRATION. IF
COMATOSE, A CUFFED ENDOTRACHEAL TUBE WILL PREVENT ASPIRATION.
CONSULT A POISON CONTROL CENTER.

Chemical Properties

Boiling Pt:B.P. Text:180F,82C
Vapor Pres:100
Vapor Density:4.6
Spec Gravity:1.020 (H*2O =1)
Evaporation Rate & Reference:<0.75 (BU AC = 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR WATER WHITE WITH CHLORINATED SOLVENT ODOR.
Percent Volatiles by Volume:60

Stability

Stability Indicator/Materials to Avoid:YES
STRONG ALKALIES, ACIDS AND SELECT AMINES. ALSO ALUMINUM.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CAN AT DECOMP TEMPS RELEASE CO, CO*2,
HCL & PHOSGENE.

Disposal

Waste Disposal Methods:WASTE LIQUID SHOULD BE SENT TO A LICENSED
RECLAIMER OR INCINERATED AT A LICENSED INCINERATOR. WIPING MATERIAL
MAY BE SENT TO LANDFILL. DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE
AND FEDERAL POLLUTION REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.